Computes per-channel surface-EMG quality metrics: signal-to-noise ratio, resting baseline noise, power-line interference ratio at 50 and 60 Hz, clipping/saturation percentage, and an ECG-contamination flag based on the periodicity of the QRS-band envelope. When the PhysioECG package is available the R-peak count it detects is reported as an additional diagnostic.

Usage

emgQualityCheck(
  x,
  ecg_score_threshold = 0.5,
  rms_window_ms = 100,
  assay_name = NULL
)

Arguments

x

A PhysioExperiment object with EMG data.

ecg_score_threshold

QRS-band periodicity score above which a channel is flagged as ECG-contaminated (default: 0.5).

rms_window_ms

Window (ms) for the moving-RMS used to estimate signal and rest levels (default: 100).

assay_name

Input assay name (default: first assay).

Value

A data.frame with one row per channel:

channel

Integer channel index.

snr_db

Signal-to-noise ratio in dB (active vs rest RMS).

baseline_noise

Resting baseline RMS (noise floor).

powerline_50, powerline_60

Fraction of total power within +/-1 Hz of 50 and 60 Hz.

powerline_ratio

The larger of powerline_50/powerline_60.

clipping_pct

Percentage of samples at the signal extremes (ADC saturation).

ecg_score

QRS-band periodicity score from 0 (none) to 1 (strong).

ecg_contamination

TRUE if ecg_score exceeds the threshold.

References

McManus, L., De Vito, G. & Lowery, M.M. (2020). "Analysis and biophysics of surface EMG for physiotherapists and kinesiologists." Frontiers in Neurology, 11, 576729. doi:10.3389/fneur.2020.576729

See also

emgRemoveECG() to remove ECG contamination, emgQCgate() for pass/fail gating, emgEnvelope()

Examples

set.seed(1)
sig <- rnorm(4000, sd = 0.02)
sig[1500:2500] <- rnorm(1001, sd = 0.4)          # a contraction
pe <- PhysioExperiment(assays = list(raw = matrix(sig, ncol = 1)),
                       samplingRate = 1000)
emgQualityCheck(pe)
#>   channel   snr_db baseline_noise powerline_50 powerline_60 powerline_ratio
#> 1       1 26.55082     0.01887598  0.006956421  0.007947266     0.007947266
#>   clipping_pct ecg_score ecg_contamination ecg_rpeaks
#> 1        0.025 0.2413754             FALSE          0